BDCOM OLT Errors & Solutions

 1. Error Message


Error Message:

Switch#write all 

Open File system failed 

write all configuration failed! rc = -1

Solution:


Switch#show telnet

NO. Remote Addr Remote Port Local Addr Local Port

1 123.136.29.153 1421 10.99.99.25 23

2 123.136.29.153 5770 10.99.99.25 23

3 123.136.29.136 49171 10.99.99.25 23

4 123.136.29.136 64213 10.99.99.25 23

5 123.136.29.136 50919 10.99.99.25 23

6 123.136.29.136 52124 10.99.99.25 23

7 123.136.29.153 55351 10.99.99.25 23

8 123.136.29.153 50926 10.99.99.25 23

Switch#clear telnet 1

Switch#clear telnet 2

 

2. Error Message ( power-off ) :


Solution:

Reason:

There is no electric power in ONU. (ONU কোনো বৈদ্যুতিক সংযোগ বা শক্তি নেই।)

Solution:

Need to re plug the power adapter ( পাওয়ার অ্যাডাপ্টার পুনরায় প্লাগ করতে হবে)


 

3. Error Message (Wire Down):



Reason:

Fiber connectivity is down at ONU

Solution:

Need to re connect the fiber connectivity in ONU

4. Error Message (Illegal License file shows at the time of NMS installation)


Solution:

1. Remove the existing NSM software

2. Reinstall the software to E or D drive but not C drive


5. Error Message:



Solution:

1. Check the TX power of GPON0/1 PON module

2. Change the GPON0/1 PON module


6. Error Message:








Reason:

The OLT always have the logging when the power up


7. Error Message:

OAM Operational Status: Operational 



Solution:


1. Switch#show epon interface epON 0/1:19 onu ctc optical-transceiver-diagnosis (No result will be shown)

2. Switch_config_epon0/1#epon onu-blacklist mac 500b.91e0.d830

3. Switch_config_epon0/1#no epon onu-blacklist mac 500b.91e0.d830

NB: The issue will be resolved if ONU RX power is within -27dB







Post a Comment