1. Error Message
Error Message:
Switch#write all
Open File system failed
write all configuration failed! rc = -1
Solution:
Switch#show telnet
NO. Remote Addr Remote Port Local Addr Local Port
1 123.136.29.153 1421 10.99.99.25 23
2 123.136.29.153 5770 10.99.99.25 23
3 123.136.29.136 49171 10.99.99.25 23
4 123.136.29.136 64213 10.99.99.25 23
5 123.136.29.136 50919 10.99.99.25 23
6 123.136.29.136 52124 10.99.99.25 23
7 123.136.29.153 55351 10.99.99.25 23
8 123.136.29.153 50926 10.99.99.25 23
Switch#clear telnet 1
Switch#clear telnet 2
2. Error Message (
Solution:
Reason:
There is no electric power in ONU. (ONU কোনো বৈদ্যুতিক সংযোগ বা শক্তি নেই।)
Solution:
Need to re plug the power adapter ( পাওয়ার অ্যাডাপ্টার পুনরায় প্লাগ করতে হবে)
3. Error Message (Wire Down):
Reason:
Fiber connectivity is down at ONU
Solution:
Need to re connect the fiber connectivity in ONU
4. Error Message (
Solution:
1. Remove the existing NSM software
2. Reinstall the software to E or D drive but not C drive
5. Error Message:
Solution:
1. Check the TX power of GPON0/1 PON module
2. Change the GPON0/1 PON module
6. Error Message:
Reason:
The OLT always have the logging when the power up
7. Error Message:
OAM Operational Status: Operational
Solution:
1. Switch#show epon interface epON 0/1:19 onu ctc optical-transceiver-diagnosis (No result will be shown)
2. Switch_config_epon0/1#epon onu-blacklist mac 500b.91e0.d830
3. Switch_config_epon0/1#no epon onu-blacklist mac 500b.91e0.d830
NB: The issue will be resolved if ONU RX power is within -27dB